Przejdź do treści
Strona korzysta z plików cookies w celu realizacji usług i zgodnie z Polityką prywatności. Możesz określić warunki przechowywania lub dostępu do plików cookies w Twojej przeglądarce.

Contracor wybór profesjonalistów PROFESSIONAL'S CHOICE PROFESSIONAL'S CHOICE

Remote Control System

RCV remote control valve


 APPLICATION


rcv1.png

The control system is operated by a single operator to turn the abrasive blasting device on and off.

DESCRIPTION


The control system includes the RCV control valve and the DMH control handle, which are connected by a double hose.

The RCV remote control valve is used to regulate the flow of compressed air while simultaneously controlling the air blow-off outside the device. Both control functions operate simultaneously while the DMH handle is pressed or released by the device operator. Air is blown out from the blast vessel through a silencer, which is included in the set.

The RCV control valve responds when the DMH handle is pressed. The blast vessel is pressurized, and the abrasive blasting cleaning process begins. When the DMH handle is released, the RCV control valve closes, the cleaning process ends, and the pressure in the blast vessel drops.

Code Name Description Net price
PLN
Quantity discount
Order quantity
≥4 ≥8 ≥12
10110870 RCV RCV remote control valve, connection 1¼”
1 790,00
-5 % -15 % -25 %
29005000 RCV-0 RCV-0 remote control valve, connection ½”
1 690,00
- - -

DMH Remote control handle

dmh1.png

The DMH control handle is attached near the nozzle and connected to the RCV control valve via a double hose.

The control lever in the sandblaster operates pneumatically, which means it uses compressed air to turn the sandblaster on and off.

How the control handle works:

  1. Compressed air: The lever is connected to the control valve (RCV), through which compressed air flows, crucial for the operation of the sandblaster.
  2. Lever mechanism: When the operator moves the control lever, it opens or closes the abrasive feed valve, which tightly seals the abrasive feeding chamber in the sandblaster.
  3. Sandblaster activation: When the abrasive feed valve to the sandblaster is in the closed position, the blasting mechanism is activated, i.e., the start of abrasive blasting onto the surface.
  4. Shutdown: After releasing the control lever, the air flow stops, causing the abrasive feed valve to drop and thus turning off the sandblaster.
Code Name Description Net price
PLN
Quantity discount
Order quantity
≥4 ≥8 ≥12
10110880 DMH Remote control handle DMH
290,00
-5 % -15 % -25 %

Remote control hose TWINLINE

twineline_1.png

Pneumatic control hose. Hose diameter – 6 mm. There are two hose length variants: 20 m and 40 m.

Code Name Description Net price
PLN
Quantity discount
Order quantity
≥3 ≥5
10112106 TWINLINE Remote control hose 20m
480,00
-5 % -10 %
10112103 TWINLINE Remote control hose 40m
800,00
-5 % -10 %